hayward blue essence troubleshootingNosso Blog

hayward blue essence troubleshootingsteve smith nfl restaurant

And water around the base. Sparking can also come directly from a short in the windings of the motor. Signature Custom Cabinetry, 240. It could also be something loose inside of the tank. I put a new 1 hp motor on the pump, and new mechanical seal in the pump, problem still the same. Well it so happens that I am having the exact same issue with the new cell. 4. leaky valve or unions in front of pump What do I need to do to fix this? Replumb your flow switch if it does not meet the distance requirements. In some instances, it could just be a bad breaker. 5. inspect all wires inside the back of motor, looking for one that is disconnected, cut, crimped, or two metal terminals touching each other. Sometimes I need to backwash and rinse before the water seems to get going enough to actually circulate, then Im able to switch to filter and it works. Nothing your husband did, hes safe to come out of the doghouse, lol. I check electrical from the panel breaker, to the timer to the circuit breakser to the switch to the outlet, through the wire to the pump and power is getting to the pump. After just a few minutes the flow slows down to almost nothing. Hi Kathleen, sounds like a leak from the shaft seal, unless water is running out of the pump exit fitting, and running down the housing and dripping off the bottom. "description": "Is your Hayward pool pump not working right? The article says: If I try to shut it off, nothing happens. Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). Check in morning and basket is half full with water trickling in basket. Hi, thats strange! You could use a small plug-in pump timer that would allow you to not unplug, just flip the switch to off. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. They have never had this issue in the pass, a salt water chlorinator was added to the system last year with no problems. The breaker on the panel tripped. Our switch seems to be getting power- a voltage tester confirms this but pump makes zero sound when switch is turned on. I took out the filter cartridge and hosed it down replaced, emptied all the baskets but still no change, only one of the jets is pushing out water, but barely. Pat. Too bad Hayward doesnt make this more clear on their installation instructions and labeling. I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. our previous pump was a hayward variable. 1. it continues to cycle this way. I would think that going to 1 hp superpump, from a 1.5 hp superpump, would not be a problem. Initially, look into the pump/strainer housing. Any suggestions what it could be. Dear Davy, my pump was working two days ago then I switched it off. Getting air in basket, changed gasket with lube still have the same issue. Cracked Seal on Case Completely Dry inside. If the motor hums, buzzes, or tries to start, but trips the breaker (or not), could be a bound-up shaft, super clogged impeller, bad capacitor, or bad motor. You will get much more visibility by. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. Read up on it and seems it happens a lot and the motor drive needs to be replaced. For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. The shaft turned with zero resistance. Recently when power came on it hums and shuts down after 6 seconds. Your pump should be connected to a bare copper wire, test it to see if there is any voltage detected in the bonding wire. I am very sure the water comes from underneath, not from plumbing fitting threads. Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. If you vacuumed the floc residue into the filter, you should be able to remove most of it with a thorough backwashing of 5 minutes or so. This year I have developed a leak under the pump housing I believe. Are you using DE powder or enough DE powder? . If the motor was submerged, it may not recover. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. Not too bad of a repair, if you want to attempt yourself. New motor sounds like the thermal overload switch (located at 12 oclock in the rear of the motor) is shutting off the motor, which is usually not a good sign, and mostly means the pump is on its way out. When I went out to drain water from the pool it wouldnt turn on. You may be removing the wrong bolts, if you are trying to loosen the 4 bolts that attach the motor to the seal plate. Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. If it is not, re-align your flow switch. Im having a problem with my super pump. How do I seal it? have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). Big mistake! It could also be just too much moisture on the motor terminals. You must log in or register to reply here. Low speed should be enough flow to activate the flow switch. Bob. Hi Bill; So you have power coming into your timer or timeclock, but on the out terminals, or the wires that lead to the pump? . Hi Stephen, could be a loose wire, not just the power wires, but other wires inside the back perhaps, or loose wires on the timeclock or breaker. Hi Craig, could be a clogged filter, needing a flush out and perhaps a filter soak in DE Filter Cleaner. Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. From the EcoStar technical guide: Check impeller and motor shaft for freedom of movement. Mine is doing same thing. How Much Salt Belongs In Your Pool heard a click at the plug. Hi Jim, check the wire connections, and the voltage coming into the motor. Thanks. Setting it up this year and the pool filter lid keeps leaking. The selector plug MUST be moved or the breaker will trip every time you try to start it up. We hope these charts help solve your Hayward pool heater problems. Disconnected the chlorination device, and direct connected it eliminating that. hopefully. Many years ago I had to replace my Hayward motor. Cap is fine, so I lost. Hayward pumps come in a variety of horsepowers, voltages and speeds. Every time I vacuum my pool and then back wash and rinse. Contact a professional for further assistance. Salt chlorine generators are great products. I even removed the outflow from the filter and ran that directly in case the filter was clogged. Is this enough to cause it not to prime or is there an issue with the impeller? This issue started immediately after I changed the filter grids on my FNS plus 60 filter. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. I have a problem when the heater warms up it blows bubbles/cloudy bubbles. Any insight would be helpful. I live in Tampa Florida. When this has been corrected, shut the power down to the pump and rest it after 15 minutes. You could remove the filter grid completely from the tank (and clean well), start the pump without the grid assembly inside (removing most of the resistance) and see how the water flows. It just started leaking at the top plumbing connection. With the information explained in this comprehensive troubleshooting guide, you can diagnose and repair your Hayward single speed or variable speed pool pump with ease! Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. Is this just a problem with the thermostat button do you think? I have an aboveground kayak saltwater system . So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. Hi Wilson, I cant find any info on that error message paused / valve change but it would sound like it thinks that either a filter valve or directional valve is being turned, so it has paused water flow. Any idea what the next most likely culprit could be? In particular, if the salt content of your pool water is too high, your metal screws, handrails, ladders, and covers will rust excessively. Ive had the pool for about a month and all has been fine but while I am ordering a new hose is there a replacement hose I can use in the meantime? I would look on the capacitor and order a new one online, with the same MFD number, or call some local electric motor repair shop and see if they have one available. hayward salt cell plumbing diagram blue essence 20 manual hayward aquarite troubleshooting guidehayward salt system troubleshooting aqua rite diagnostic codes Blue essence salt chlorine generator owner's manual Salt Chlorinator Cell Replacement, Salt Water System Parts, Pool Light, Pool Alarm, Pool. Pump had been working fine, but this week started making a kind of rhythmic buzzing sound while running. I basically removed my old pump and instalked the new one. Checked pump, and appeared that pump had to keep priming . When you first turn it on it works great with strong suction. However, we are not able to remove the pump. Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. It is a Hayward Super Pump 1.5 HP (model #SP2610X15). I think I have some air leakage on my supply side of my Hayward Super Pump. Let everything dry and put the pump on again and it just hums. When starting up when the pump gets to 75% almost pushing the air out the pump starts to pulse with a click in the motor like the click you hear when a motor starts up.

Magalenha Significado, Articles H



hayward blue essence troubleshooting

hayward blue essence troubleshooting